Seitenansicht 101
IB-23C650
SETUP
Table 9. Ramp/Soak Profile Setup Menu
Step Step Description
Top
Display
7.1.1
Segment 1 Start Value.
UP
or
DN
sets value.
SCRL
to advance to Step 7.1.2.
SEG 1
7.1.2
Segment 1 End Value.
UP
or
DN
sets value.
SCRL
to advance to:
Step 7.1.3 if start and end values are the same,
or
Step 7.1.4 if start and end values are different.
SEG 1
7.1.3
Segment 1 Soak Time.
UP
or
DN
sets time.
SCRL
to advance to:
Step 7.1.5 if relay A is set for ramp/soak
(in Relays), or
Step 7.1.6 if relay B is set for ramp/soak, or
Step 7.1.7 if relay C is set for ramp/soak, or
Step 7.1.8 otherwise.
SEG 1
7.1.4
Segment 1 Ramp Rate.
UP
or
DN
sets rate.
SCRL
to advance to:
Step 7.1.5 if relay A is set for ramp/soak (in
Relays), or
Step 7.1.6 if relay B is set for ramp/soak, or
Step 7.1.7 if relay C is set for ramp/soak, or
Step 7.1.8 otherwise.
SEG 1
96